Slides and Notes 02-May-2008

I have a working MEp1New.sdf. It is used in conjunction with a data file new.dat, in which recent ME+1 results are used (but with fake data for HSLM3--ambient light saturation problems). It uses fake z-sensor data for distances between the MAB structure and the transfer plate, and photogrammetry positions for the transfer plates.

This may also be found in my public area on lxplus.

ChamberCocoaCocoaCocoaDaveDave
NameCMS-xCMS-yCMS-zCMS-xCMS-y
emu/slm_p11/mep12_023640.8564641.991756770.63663640.859641.982
emu/slm_p11/mep13_035592.64362035.41456867.29835592.6262035.482
emu/slm_p12/mep12_081264.44883474.06976769.3241264.4573474.0671
emu/slm_p12/mep13_091033.57095861.08696866.00571033.5345861.0969
emu/slm_p13/mep12_14-2376.39942832.08846770.3195-2376.4022832.086
emu/slm_p13/mep13_14-3825.55554559.15136867.5201-3825.51794559.1735
emu/slm_p14/mep12_20-3640.8582-641.985516769.2411-3640.859-641.982
emu/slm_p14/mep13_20-5861.0747-1033.57396866.9007-5861.119-1033.4089
emu/slm_p15/mep12_26-1264.4642-3474.06556767.2289-1264.457-3474.067
emu/slm_p15/mep13_27-1033.5147-5861.1026865.2382-1033.534-5861.097
emu/slm_p16/mep12_322376.4161-2832.07166765.80812376.406-2832.0857
emu/slm_p16/mep13_334559.0474-3825.65946864.19144559.092-3825.615

Deviations from the ideal: The central peak has an rms of 25 microns. The data is from March.